This is a working overview of Quality control, written for readers who want more than a one-paragraph summary but less than a textbook.
Reviewed 2026-08-01. Anything still debated is marked as such rather than presented as settled.
Key performance measures include retention time, peak area, peak height, resolution, tailing factor, and plate count. Retention time helps identify a peak under fixed conditions, but confirmation often requires a second method or detector. Peak area and height relate to concentration through calibration curves, which may be linear or nonlinear depending on the detector response. Resolution describes separation between adjacent peaks, while tailing factor and plate count describe peak shape and column efficiency. Performance checks verify these values before and during a run to confirm that the instrument is performing within limits.
High-performance liquid chromatography testing separates components of a liquid sample by forcing a mobile phase through a packed column. The stationary phase inside the column interacts with analytes to different degrees, so each compound exits at a characteristic retention time. A pump delivers solvent at controlled flow and pressure, while an injector introduces a precise sample volume. Detectors such as ultraviolet-visible, fluorescence, refractive index, or mass spectrometric instruments record the separated bands. The resulting chromatogram provides qualitative and quantitative information about the mixture.
Separation modes differ by the chemistry of the stationary phase and the composition of the mobile phase. Reversed-phase testing uses a nonpolar column and polar solvents, making it common for pharmaceutical, environmental, and food analytes. Normal-phase testing uses a polar column and nonpolar solvents for compounds that are poorly retained in reversed-phase systems. Ion-exchange and ion-pair methods separate charged species, while size-exclusion methods sort molecules by hydrodynamic volume. Gradient elution changes solvent strength over time to resolve complex mixtures, and isocratic elution holds solvent composition constant for simpler assays.
Routine HPLC testing depends on controlled reagents, calibrated instruments, and documented procedures. Columns degrade over time, so retention times and peak shapes are monitored for drift. Mobile phases are filtered and degassed to prevent pump damage and detector noise. Reference standards must be traceable and stored under suitable conditions. Data handling systems record injections, calculations, and audit trails. Quality control samples interspersed with unknowns help detect errors during a run.
Developing an HPLC method begins with defining the purpose, such as quantifying a main component, measuring impurities, or confirming identity. Analysts select separation mode, column, mobile phase, detection, and sample preparation based on analyte properties and matrix. Experiments vary solvent strength, pH, buffer type, and temperature to achieve resolution between critical peaks. The goal is a robust method that produces reliable results across instruments and operators. Method development often involves trial runs and statistical optimization.
Validation demonstrates that a method is suitable for its intended use. Typical performance characteristics include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantitation, and robustness. Regulators and standards organizations provide frameworks, but specific requirements depend on the application and jurisdiction. System suitability tests are run before sample analysis to confirm resolution, peak symmetry, retention time repeatability, and sensitivity. A validated method is not permanently fixed; changes may require partial or full revalidation.
| Property | Value | Notes |
|---|---|---|
| Separation mode | Reversed-phase | Common for polar and moderately polar analytes |
| Typical column length | 100-250 mm | Shorter columns can reduce run time |
| Particle size | 3-5 micrometers | Smaller particles improve efficiency but raise pressure |
| Flow rate | 0.5-2.0 mL/min | Depends on column dimensions and pressure limits |
| Detection | UV-Vis absorbance | Widely used for compounds with chromophores |
Routine quality control uses system suitability, blank injections, check standards, and control samples to detect drift or contamination. System suitability criteria may specify minimum resolution, maximum tailing factor, and a permitted range for repeated injections. Blank injections reveal carryover or solvent contamination, while check standards confirm calibration accuracy over a batch. Control samples with known analyte levels can show whether results remain within statistical limits. When a control result falls outside limits, the analyst investigates the cause and may invalidate affected results before repeating the batch.
Documentation and traceability are central to regulated HPLC testing. Records typically include instrument logs, column history, mobile-phase preparation, sample preparation, injection sequences, raw chromatograms, and audit trails. Electronic systems may require user access controls, time-stamped changes, and backup procedures. Training records show that analysts are qualified for assigned methods. Audits and inspections check whether written procedures match actual practice and whether deviations are documented. These controls support reproducibility and allow results to be reconstructed if questions arise later.
Method validation establishes that an HPLC procedure is suitable for its intended purpose. Typical parameters include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantitation, robustness, and solution stability. Accuracy reflects closeness to a reference value, while precision reflects agreement among repeated measurements. Specificity shows whether the method can measure the analyte without interference from matrix components. Validation is documented through protocols and reports, and the required extent depends on the method's use and regulatory context.
HPLC testing is not a single fixed procedure; it is a family of separation modes. Reversed-phase, normal-phase, ion-exchange, size-exclusion, and affinity chromatography each suit different analyte properties. Reversed-phase methods dominate because they handle many neutral and moderately polar compounds. Detection can be optical, electrochemical, or mass spectrometric, and the detector dictates what information is available. Coupling with mass spectrometry increases selectivity and enables identification when standards are unavailable. The technique cannot separate every mixture without adjustment.
HPLC testing is an analytical technique used to separate, identify, and quantify components in a liquid sample. It relies on a pressurized mobile phase that carries the sample through a column packed with stationary phase. Different compounds travel at different rates because of interactions with the stationary and mobile phases. The resulting signal versus time is a chromatogram. Peak position indicates identity under specified conditions, while peak area or height relates to amount.
Practical HPLC testing depends on careful sample preparation and instrument maintenance. Samples may require filtration, dilution, pH adjustment, or extraction to avoid column damage and matrix interference. Mobile phases are degassed and filtered, and columns are equilibrated before injection. Common problems include peak tailing, baseline drift, ghost peaks, carryover, and co-elution of analytes. Documentation of instrument logs, calibration records, and electronic audit trails supports data integrity and traceability. Ongoing training and routine maintenance help reduce variability between analysts and laboratories.
Quality control laboratories use HPLC to check identity, purity, concentration, and stability of raw materials and finished products. A validated method specifies the column, mobile phase, flow rate, detection wavelength, injection volume, and run time. Samples are prepared and compared against reference standards of known concentration. The resulting chromatogram provides quantitative data, such as assay values and impurity levels. This approach is common in pharmaceutical, food, environmental, and industrial testing where consistent measurements are required.
Validation establishes that a method is suitable for its intended purpose. Typical parameters include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantification, robustness, and stability of standards and samples. Acceptance criteria are defined in advance, and results are documented in a validation report. Regulatory guidance for pharmaceuticals, foods, and environmental testing differs, so the applicable framework must be identified. Ongoing verification uses control samples and trend charts after validation. Method transfer to another laboratory may require partial revalidation.
Routine quality control includes blanks, duplicates, spiked samples, and certified reference materials. Calibration curves are prepared with standards at several concentrations, and the detector response is checked for linearity. Carryover, column aging, mobile phase evaporation, and temperature drift can shift retention times or peak areas. Maintenance such as replacing seals, filters, and columns helps prevent failures. Records of injections, integration, and deviations support traceability. Audits may request raw data and instrument logs for each batch.
Developing an HPLC test begins with defining the analytes, matrix, and required reporting limits. Chemists select a separation mode, column chemistry, mobile phase composition, flow rate, and detection wavelength or mass transition. Experiments then adjust these variables to achieve adequate retention, resolution, and peak shape. System suitability tests confirm that the instrument and method perform consistently before sample analysis. Without suitable resolution, quantitative results may be unreliable. Preliminary runs often use scouting gradients to locate retention windows.
Chromosome walking can be used for the purpose of cloning a gene. It does this by using the known gene’s markers that are closest and can therefore be used in techniques like isolating DNA sequences and aiding in the sequencing and cloning of the DNA of organisms. Chromosome walking is also useful when it comes to filling in the gaps that may be present in genomes by locating clones that overlap with a library clone end. This means that for chromosome walking to be carried out, it requires a clone library of a genomic format. This is why Vectorette PCR is one of the methods that can be used to create this library for chromosome walking to occur. Vectorette PCR comes in handy when it is necessary to obtain the regions that are both upstream and downstream and flank a sequence that is already known. By obtaining these regions, it provides the library of a genomic format that chromosome walking requires.
GOT1/cAST, the cytosolic isoenzyme derives mainly from red blood cells and heart. GOT2/mAST, the mitochondrial isoenzyme is present predominantly in liver. These isoenzymes are thought to have evolved from a common ancestral AST via gene duplication, and they share a sequence homology of approximately 45%. AST has also been found in a number of microorganisms, including E. coli, H. mediterranei, and T. thermophilus. In E. coli, the enzyme is encoded by the aspCgene and has also been shown to exhibit the activity of an aromatic-amino-acid transaminase (EC 2.6.1.57).
Patterns of protein expression in levitated cultures resemble the patterns observed in-vivo. For example, as shown in the figure on the right, N-cadherin expression in levitated human glioblastoma (GBM) cells was similar to that seen in human tumor xenografts grown in immunodeficient mice (comparing the left and middle images), while standard 2D culture showed much weaker expression that did not match xenograft distribution (comparing the left and right images). The transmembrane protein N-cadherin is often used as an indicator of in-vivo-like tissue assembly in 3D culturing. Referring to the figure, in the mouse and levitated culture (left and middle image), N-cadherin is clearly concentrated in the membrane, and also present in cytoplasm and cell junctions, whereas the 2D system (right image) shows N-cadherin in the cytoplasm and nucleus, but absent from the membrane.
Because lipopolysaccharides are potent inflammatory agents, and the action of antibiotics can result in the release of these compounds, the binding capacity of BPI was explored as a possible means of reducing injury. Xoma Ltd. developed a recombinant 21kDa portion of the BPI molecule called rBPI21, NEUPREX, or opebecan. In a trial, it was found to decrease the mortality of Gram-negative bacterial-induced sepsis. Studies suggest that its binding activity is not the means by which it mediates its protective effect. Studies show biological effects with Gram-positive bacteria and even in infection by the protozoan, Toxoplasma gondii. The N-terminal portion of murine BPI (199 amino acids) genetically fused to Halobacterium sp. NRC-1 GvpC protein was bound to the surface of gas vesicle nanoparticles (GVNPs) and tested for protective activity using a murine model of endotoxic shock. Depending on the time of delivery and exposure to lethal concentrations of lipopolysaccharide (LPS) and D-galactosamine, the treatment resulted in increased survival and reduced symptoms of inflammation, including inflammatory anemia, recruitment of neutrophils, liver apoptosis as well as increased pro-inflammatory serum cytokine levels. When administered via footpad and before LPS exposure, there was 100% survival of the experimental cohort.
Protein microarrays and high throughput (HT) mass spectrometry (MS) can provide a snapshot of the proteins present in a biological sample. The former approach faces similar problems as with microarrays targeted at mRNA, the latter involves the problem of matching large amounts of mass data against predicted masses from protein sequence databases, and the complicated statistical analysis of samples when multiple incomplete peptides from each protein are detected. Cellular protein localization in a tissue context can be achieved through affinity proteomics displayed as spatial data based on immunohistochemistry and tissue microarrays.
Sources: en.wikipedia.org
Afamelanotide is a synthetic tridecapeptide and a structural analogue of α-melanocyte stimulating hormone (α-MSH). It is a melanocortin receptor agonist and binds predominantly to the MC1 receptor. Its binding lasts longer than that of α-MSH. This results in part from afamelanotide's resistance to immediate degradation by serum or proteolytic enzymes. It is thought to cause skin darkening by binding to the MC1 receptor which in turn drives melanogenesis. It has a short half-life of approximately 30 minutes. After administration with implantation into the skin, the majority of the drug is released within two days, with 90% released by the fifth day. By the tenth day, no drug is detectable in plasma. The details of drug distribution, metabolism and excretion remain unclear (as of 2026), but since it is a small peptide with a short half-life, it is expected that it is quickly broken down into shorter peptide fragments and amino acids.
CPC Scientific Group was founded in 2001, and the US company established in 2005 by Shawn Lee, Ph.D., and began by supplying research-grade custom peptides, catalog peptides, and Fmoc-protected amino acids. In 2006, the company opened a GMP (Good Manufacturing Practice) facility in Hangzhou, China to support the production of peptides for clinical use. The Hangzhou site underwent its first inspection by the U.S. Food and Drug Administration (FDA) in 2011, after which CPC Scientific began supplying pharmaceutical-grade peptides to clients in the United States. On March 17, 2016, the company passed a fourth FDA inspection. In 2024, the company completed a fifth U.S. FDA inspection and was also inspected by Australia’s Therapeutic Goods Administration (TGA). In 2025, CPC Scientific obtained ISO 22716:2007 Cosmetic GMP certification for the manufacture of peptide ingredients for cosmetic applications. CPC Scientific is part of Medtide Inc., which was listed on the Main Board of the Hong Kong Stock Exchange on June 30, 2025 (Stock Code: 03880).
Within the field of supramolecular polymerization, Schmatloch et al. used automated synthesis to create main-chain supramolecular coordination polymers, reacting bis(2,2′:6′,2″-terpyridine)-functionalized poly(ethylene oxide) with various metal(II) acetates. From this, it was revealed that classical laboratory approaches could be transferred to automatic synthesis, optimizing the processes to increase efficiency and aid with reproducibility.
Automated synthesis or automatic synthesis is a set of techniques that use robotic equipment to perform chemical synthesis using a robotic system run using software control. Automating processes allows for higher efficiency and product quality although automation technology can be cost-prohibitive and there are concerns regarding overdependence and job displacement. Chemical processes were automated throughout the 19th and 20th centuries, with major developments happening in the previous thirty years, as technology advanced. Tasks that are performed may include: synthesis in variety of different conditions, sample preparation, purification, and extractions. Applications of automated synthesis are found on research and industrial scales in a wide variety of fields including polymers, personal care, and radiosynthesis.
Sources: en.wikipedia.org
Acanthosis nigricans-muscle cramps-acral enlargement syndrome, also known as Acanthosis nigricans-insulin resistance-muscle cramps-acral enlargement syndrome, is an extremely rare genetic disorder which is characterized by the appearance of acanthosis nigricans, insulin resistance, muscle cramps of severe intensity, and acral hypertrophy/enlargement. Only 2 cases have been reported in medical literature. It was first discovered when Jeffrey Flier and his colleagues described two siblings of the opposite sex with the symptoms mentioned above. (plus: large, chunky hands), the sister had virilized polycystic ovaries. After being treated with dilantin, the cramps' severity lowered and the brother's insulin resistance also lowered. The inheritance pattern of this disorder is thought to be autosomal recessive.
Eq. 3 This means that coconut oil with an abundance of medium chain fatty acids (mainly lauric acid) contain more fatty acids per unit of weight than, for example, olive oil (mainly oleic acid). Consequently, more ester saponifiable functions were present per g of coconut oil, which means more KOH is required to saponify the same amount of matter, and thus a higher SV. The calculated molecular weight (Eq. 3) is not applicable to fats and oils containing high amounts of unsaponifiable material, free fatty acids (> 0.1%), or mono- and diacylglycerols (> 0.1%).
The tine test, which uses a "button" with four to six short needles coated with tuberculin instead of an injection. It is easier to administer. It has comparable results if "doubtful" indications are treated as positive. The US CDC and the American Thoracic Society believe that it is less reliable because the amount of tuberculin that enters the skin cannot be accurately determined, despite the aforementioned results. The Heaf test, a test similar to the tine test formerly used in the United Kingdom. A spring-loaded instrument with six needles is used. It stopped being used in 2005 as the manufacturer deemed the production of this instrument financially unsustainable.
ACS first established technical divisions in 1908 to foster the exchange of information among scientists who work in particular fields of chemistry or professional interests. Divisional activities include organizing technical sessions at ACS meetings, publishing books and resources, administering awards and lectureships, and conducting other events. The original five divisions were 1) organic chemistry, 2) industrial chemists and chemical engineers, 3) agricultural and food chemistry, 4) fertilizer chemistry, and 5) physical and inorganic chemistry. As of 2016, there are 32 technical divisions of ACS.
Early measurements of coaxial stacking were performed using biochemical assays that studies the relative migration of different nucleic acid molecules based on their conformation and the kind of interactions present. Short DNA molecules containing nicks that could still stack coaxially migrated faster than DNA molecules containing gaps and thus had no coaxial stacking. This could be explained by polymeric properties of DNA where are more rigid rod like molecule will migrate faster along an electrical gradient in a matrix compared to a more flexible molecule. Development of newer techniques such as optical tweezers and the ability to fold DNA nanostructures led to measurement so of DNA bundles and their ability to stack with each other. The force needed to pull these bundles apart using optical tweezers could then be analyzed to measure the base-pair stacking energies. These measurements were performed mainly under non-equilibrium conditions and various extrapolations were made to arrive at the exact values of coaxial stacking between bases. Recent single-molecule studies using DNA nanostructures and DNA-PAINT super-resolution microscopy has allowed for measurement of these interaction between dinucleotides using in-depth kinetic analysis of binding times of short DNA molecules to their complimentary sequences in the presence or absence of DNA-stacking interactions.
Sources: en.wikipedia.org
It measures the amounts and identities of compounds in liquid samples by separation and detection. Depending on the detector and reference standards, results can be qualitative or quantitative. The technique is used in fields such as pharmaceutical analysis, food safety, and environmental monitoring.
Performance checks confirm that the chromatographic system works within preset limits before results are accepted. They examine factors such as peak resolution, tailing, and repeatability. If criteria fail, the run may need correction or repetition.
Retention time alone is not definitive proof because other compounds can elute at similar times. Confirmation usually uses a second method, a different column, or a detector such as mass spectrometry. Authentic standards strengthen identification.
It is a set of checks performed before or during an HPLC run to confirm the system works as expected. Parameters may include resolution, tailing factor, theoretical plates, and retention time precision. Failure can trigger maintenance, method adjustment, or repeat analysis.